RoDent : Robotic Dentistry : Computer aided dental implant positioning system

952 visningar
uppladdat: 2007-01-01
Inactive member

Inactive member

Nedanstående innehåll är skapat av Mimers Brunns besökare. Kommentera arbete
A study was carried in conjunction with the Orthodontic department at Halmstad General Hospital in Sweden to investigate the possibility of reducing cost and manufacture time of dental implant drill guides. The current system involves sending a digital image in STL format to the Materialise factory in Belgium where information of the position of dental implants is translated onto a moulded mouthpiece. Drill guides are placed in the mouth piece which is then returned to the surgeon. The mouthpiece complete with drill guides is then placed in the patients mouth and used as a guide for the implant drill holes. The cost of 10000 sek and a turnaround time of 2 weeks gave rise to the need for a faster and cheaper solution. A new mouthpiece was designed comprising of a solid cube which could be clearly seen on the x-ray. Linearisation of the cube faces is used to find a reference point from which to drive a 5 axis drilling platform. The mouthpiece is placed in the drill platform which is driven by stepper motors which in turn are controlled by a microcontroller. Co-ordinates are entered via a PC interface. The PC software then translates these co-ordinates into motor steps which are sent to the microcontroller. The drill platform then positions the mouthpiece in order to drill guide holes for the dental implants. The study showed that the machine design gave an acceptable degree of accuracy and repeatability. Further enhancements could be made by automating the detection of the cube using image analysis techniques. The study was also limited by the lack of graphical and geometrical data concerning the position of the implant. For the purpose of this study the co-or...

...läs fortsättningen genom att logga in dig.

Medlemskap krävs

För att komma åt allt innehåll på Mimers Brunn måste du vara medlem och inloggad.
Kontot skapar du endast via facebook.

Källor för arbetet

Saknas

Kommentera arbetet: RoDent : Robotic Dentistry : Computer aided dental implant positioning system

 
Tack för din kommentar! Ladda om sidan för att se den. ×
Det verkar som att du glömde skriva något ×
Du måste vara inloggad för att kunna kommentera. ×
Något verkar ha gått fel med din kommentar, försök igen! ×

Kommentarer på arbetet

Inga kommentarer än :(

Liknande arbeten

Källhänvisning

Inactive member [2007-01-01]   RoDent : Robotic Dentistry : Computer aided dental implant positioning system
Mimers Brunn [Online]. https://mimersbrunn.se/article?id=15179 [2024-04-29]

Rapportera det här arbetet

Är det något du ogillar med arbetet? Rapportera
Vad är problemet?



Mimers Brunns personal granskar flaggade arbeten kontinuerligt för att upptäcka om något strider mot riktlinjerna för webbplatsen. Arbeten som inte följer riktlinjerna tas bort och upprepade överträdelser kan leda till att användarens konto avslutas.
Din rapportering har mottagits, tack så mycket. ×
Du måste vara inloggad för att kunna rapportera arbeten. ×
Något verkar ha gått fel med din rapportering, försök igen. ×
Det verkar som om du har glömt något att specificera ×
Du har redan rapporterat det här arbetet. Vi gör vårt bästa för att så snabbt som möjligt granska arbetet. ×