One of the most used irradiation techniques in modern radiation therapy is step-and-shoot IMRT. The accuracy of this technique when delivering complex dose distributions strongly depends on the size of the subfields. The aims of this study is to determine the minimum size of subfields that can be used efficiently in Step-and-Shoot IMRT, to investigate the validation process for beam delivery and treatment planning dose calculations, and to find recommendations for practical clinical implementations.Two different detectors, a CC04 ion chamber and a SFD stereotactic diode, have been used for measuring head scatter factors in air (Sc), total output factors (Scp) and dose profiles in water for a wide range of field sizes. The measurements were compared to calculations done with a pre-release version of the Nucletron MasterPlanTM v 3.1 treatment planning system that employs a novel, high resolution fluence modelling for both its pencil beam and collapsed cone dose calculation algorithms. Collimator settings were explicitly checked using FWHM film measurements with a build-up sheet of tungsten placed close to the treatment head to reduce the influence from lateral electron transport and geometrical penumbra. An analysis of the influence and sensitivity of Scp for small fields with respect to the linear accelerator source size and shape was also made.The measurements with the ionization chamber and the stereotactic diode showed good agreements with each other and with the treatment planning system calculations for field sizes larger than 2×2 cm2. For small field sizes, measurements with different detectors yielded different results. Calculations showed agreements with measurements with the smallest detector, provided careful field size calibration and commissioning of calculation parameters. Uncertainties in collimator settings and source characteristics were shown to yield large uncertainties in Scp for fields smaller than 2×2 cm2.The treatment planning system was found to properly handle small subfields but results were very sensitive to uncertainties in source size, as well as calibration and reproducibility of the collimator settings. Therefore if subfields smaller than 2×2 cm2 are to be used in IMRT extra care should...

...läs fortsättningen genom att logga in dig.

Medlemskap krävs

För att komma åt allt innehåll på Mimers Brunn måste du vara medlem och inloggad.
Kontot skapar du endast via facebook.

Källor för arbetet

Saknas

Kommentera arbetet: Commissioning and validation of small subfields in Step-and-shoot IMRT

 
Tack för din kommentar! Ladda om sidan för att se den. ×
Det verkar som att du glömde skriva något ×
Du måste vara inloggad för att kunna kommentera. ×
Något verkar ha gått fel med din kommentar, försök igen! ×

Kommentarer på arbetet

Inga kommentarer än :(

Liknande arbeten

Källhänvisning

Inactive member [2008-01-01]   Commissioning and validation of small subfields in Step-and-shoot IMRT
Mimers Brunn [Online]. https://mimersbrunn.se/article?id=18303 [2024-05-05]

Rapportera det här arbetet

Är det något du ogillar med arbetet? Rapportera
Vad är problemet?



Mimers Brunns personal granskar flaggade arbeten kontinuerligt för att upptäcka om något strider mot riktlinjerna för webbplatsen. Arbeten som inte följer riktlinjerna tas bort och upprepade överträdelser kan leda till att användarens konto avslutas.
Din rapportering har mottagits, tack så mycket. ×
Du måste vara inloggad för att kunna rapportera arbeten. ×
Något verkar ha gått fel med din rapportering, försök igen. ×
Det verkar som om du har glömt något att specificera ×
Du har redan rapporterat det här arbetet. Vi gör vårt bästa för att så snabbt som möjligt granska arbetet. ×