Portable capillary electrophoresis system with LED-absorbance photometric and LED-induced fluorescence detection : Design, characterisation and testing

691 visningar
uppladdat: 2008-01-01
Inactive member

Inactive member

Nedanstående innehåll är skapat av Mimers Brunns besökare. Kommentera arbete
Capillary electrophoresis (CE) has a wide range of applications in the field of analytical chemistry. In general the most expensive part in a CE system is the detector due to the fact that the detector must have a high sensitivity for small detection volumes and low concentrations. Building portable instruments is one way to make the instruments cheaper and has the advantage that they can be used virtually everywhere. However, downscaling of CE instruments puts some extra demands on the detector. This report describes the design and building of two homemade light-emitting diode (LED) based detectors; a LEDabsorbance photometric detector (LED-AP) and a LED-induced fluorescence (LED-IF) detector. The main goal was to install them inside a portable CE and make a simple separation. The performance of the two detectors had to be evaluated before the main goal could be achieved. p-Nitrophenol was used to create a sensitivity graph for the LED-AP detector, calculating the upper linearity to 5.6 mM when the sensitivity had dropped 10 % caused by non-linearity. The sensitivity graph also showed that the detector had an effective pathlength of 74.2 µm and a stray light of 4.5 % for a 75 µm i.d fused-silica capillary. The LED-IF detector was evaluated by determining the limit of detection (LOD) for fluorescein, at a signal to noise ratio of 3. The LOD was 0.72 µM ± 0.01 µM when immersion oil was used to limit the light scattering from the optic fibres in to the capillary and 0.58 µM ±0.02 µM when silicone oil was used. Without doing any improvements only the LED-AP detector could be used in the portable CE. As a common application area for portable CE in...

...läs fortsättningen genom att logga in dig.

Medlemskap krävs

För att komma åt allt innehåll på Mimers Brunn måste du vara medlem och inloggad.
Kontot skapar du endast via facebook.

Källor för arbetet

Saknas

Kommentera arbetet: Portable capillary electrophoresis system with LED-absorbance photometric and LED-induced fluorescence detection : Design, characterisation and testing

 
Tack för din kommentar! Ladda om sidan för att se den. ×
Det verkar som att du glömde skriva något ×
Du måste vara inloggad för att kunna kommentera. ×
Något verkar ha gått fel med din kommentar, försök igen! ×

Kommentarer på arbetet

Inga kommentarer än :(

Liknande arbeten

Källhänvisning

Inactive member [2008-01-01]   Portable capillary electrophoresis system with LED-absorbance photometric and LED-induced fluorescence detection : Design, characterisation and testing
Mimers Brunn [Online]. https://mimersbrunn.se/article?id=20509 [2024-05-05]

Rapportera det här arbetet

Är det något du ogillar med arbetet? Rapportera
Vad är problemet?



Mimers Brunns personal granskar flaggade arbeten kontinuerligt för att upptäcka om något strider mot riktlinjerna för webbplatsen. Arbeten som inte följer riktlinjerna tas bort och upprepade överträdelser kan leda till att användarens konto avslutas.
Din rapportering har mottagits, tack så mycket. ×
Du måste vara inloggad för att kunna rapportera arbeten. ×
Något verkar ha gått fel med din rapportering, försök igen. ×
Det verkar som om du har glömt något att specificera ×
Du har redan rapporterat det här arbetet. Vi gör vårt bästa för att så snabbt som möjligt granska arbetet. ×