Analysisof a DH system in Sörbyskolan : School placed in Gävle

1065 visningar
uppladdat: 2008-01-01
Inactive member

Inactive member

Nedanstående innehåll är skapat av Mimers Brunns besökare. Kommentera arbete
Electricity and district heating are the most important energy carriers for the residential and service sector in Sweden. Today, district heating supplies about half of the total heating requirement of residential and commercial premises in Sweden. The aim of this paper is the analysis of the heating system of a school, placed in Gävle, Sweden. The heat is delivered to the school by a district heating network.First of all, the Heat Balance must be done, with the purpose of obtain the best knowledge of the present situation in the school. The calculations about the transmission and ventilation losses and the internal heating generated have been showed. After this, the point of view has been focused on the district heating system itself. It is means, the distribution pipe system inside the school. The efficiency and accuracy of the net will be analysed and discussed.Three possible ways to improve the net will be showed. The first of all is the most simple: just take the pipe system and try to reduce the waste heat, the heat losses; the second choice is to make a new connection to the district heating network, joining all the buildings with one connection for each building –five more- instead of only the connection that exists at the moment when this paper was written; the third option seems as a different model of the second, it is means to divide all the school in two bigger parts and make another connection to the district heating network with the purpose of dividing the heating system in two equal parts.Thanks to the heat balance done in the school and in the district heating system, it is possible to know the waste of heat. Mainly, these losses are found in the district heating net. The amount of waste is around 17%, a really high amount of energy wasted, which must be reduced. According to the data of the company Gävle Energy, the waste in old buildings like the school which is under study in this paper, usually is between 15% and 20% of the supplied energy. So, this showed the accuracy of the method used to make this paper.According to the possibilities of improvement, it will depend on the ultimate decision of the Gävle Fastigheter, company which owns the school, to choose the way that could be better for their own interest. However, in this paper the prices and possible pay-back times are showed, in order to provide better information.Although the best solution has a total cost of 1...

...läs fortsättningen genom att logga in dig.

Medlemskap krävs

För att komma åt allt innehåll på Mimers Brunn måste du vara medlem och inloggad.
Kontot skapar du endast via facebook.

Källor för arbetet

Saknas

Kommentera arbetet: Analysisof a DH system in Sörbyskolan : School placed in Gävle

 
Tack för din kommentar! Ladda om sidan för att se den. ×
Det verkar som att du glömde skriva något ×
Du måste vara inloggad för att kunna kommentera. ×
Något verkar ha gått fel med din kommentar, försök igen! ×

Kommentarer på arbetet

Inga kommentarer än :(

Liknande arbeten

Källhänvisning

Inactive member [2008-01-01]   Analysisof a DH system in Sörbyskolan : School placed in Gävle
Mimers Brunn [Online]. https://mimersbrunn.se/article?id=27986 [2024-04-28]

Rapportera det här arbetet

Är det något du ogillar med arbetet? Rapportera
Vad är problemet?



Mimers Brunns personal granskar flaggade arbeten kontinuerligt för att upptäcka om något strider mot riktlinjerna för webbplatsen. Arbeten som inte följer riktlinjerna tas bort och upprepade överträdelser kan leda till att användarens konto avslutas.
Din rapportering har mottagits, tack så mycket. ×
Du måste vara inloggad för att kunna rapportera arbeten. ×
Något verkar ha gått fel med din rapportering, försök igen. ×
Det verkar som om du har glömt något att specificera ×
Du har redan rapporterat det här arbetet. Vi gör vårt bästa för att så snabbt som möjligt granska arbetet. ×