Accuracy and precision of a technique to assess residual limb volume with a measuring-tape

633 visningar
uppladdat: 2003-01-01
Inactive member

Inactive member

Nedanstående innehåll är skapat av Mimers Brunns besökare. Kommentera arbete
Transtibial stump volume can change dramatically postoperatively and jeopardise prosthetic fitting. Differences between individuals make it hard to give general recommendations of when to fit with a definitive prosthesis. Measuring the stump volume on every patient could solve this, but most methods for volume assessments are too complicated for clinical use.The aim of this study was to evaluate accuracy and intra- and interrater precision of a method to estimate stump volume from circumferential measurements. The method approximates the stump as a number of cut cones and the tip as a sphere segment.Accuracy was evaluated theoretically on six scanned stump models in CAPOD software and manually on six stump models. Precision was evaluated by comparing measurements made by four CPOs on eight stumps. Measuring devices were a wooden rule and a metal circumference rule. The errors were estimated with intraclass correlation coefficient (ICC), where 0,85 was considered acceptable, and a clinical criterion that a volume error of ±5% was acceptable (5% corresponds to one stocking).The method was accurate on all models in theory but accurate on only four models in reality. The ICC was 0,95-1,00 for intrarater precision but only 0,76 for interrater precision. Intra- and interrater precision was unsatisfying when using clinical criteria. Variations between estimated tip heights and circumferences were causing the errors.The method needs to be developed and is not suitable for stumps with narrow ends. Using a longer rule (about 30 cm) with a set square end to assess tip heights is r...

...läs fortsättningen genom att logga in dig.

Medlemskap krävs

För att komma åt allt innehåll på Mimers Brunn måste du vara medlem och inloggad.
Kontot skapar du endast via facebook.

Källor för arbetet

Saknas

Kommentera arbetet: Accuracy and precision of a technique to assess residual limb volume with a measuring-tape

 
Tack för din kommentar! Ladda om sidan för att se den. ×
Det verkar som att du glömde skriva något ×
Du måste vara inloggad för att kunna kommentera. ×
Något verkar ha gått fel med din kommentar, försök igen! ×

Kommentarer på arbetet

Inga kommentarer än :(

Källhänvisning

Inactive member [2003-01-01]   Accuracy and precision of a technique to assess residual limb volume with a measuring-tape
Mimers Brunn [Online]. https://mimersbrunn.se/article?id=38519 [2024-04-27]

Rapportera det här arbetet

Är det något du ogillar med arbetet? Rapportera
Vad är problemet?



Mimers Brunns personal granskar flaggade arbeten kontinuerligt för att upptäcka om något strider mot riktlinjerna för webbplatsen. Arbeten som inte följer riktlinjerna tas bort och upprepade överträdelser kan leda till att användarens konto avslutas.
Din rapportering har mottagits, tack så mycket. ×
Du måste vara inloggad för att kunna rapportera arbeten. ×
Något verkar ha gått fel med din rapportering, försök igen. ×
Det verkar som om du har glömt något att specificera ×
Du har redan rapporterat det här arbetet. Vi gör vårt bästa för att så snabbt som möjligt granska arbetet. ×