Aquametry in granulate materials

824 visningar
uppladdat: 2005-01-01
Inactive member

Inactive member

Nedanstående innehåll är skapat av Mimers Brunns besökare. Kommentera arbete
On-line aquametry, or water content measurement, is of importance to several branches of industry. In general, on-line measurements of water content are needed in order to improve the performance of different algorithms used for process control. The problem at hand might seem straightforward at first glance. However, currently there exists no standardized "of the shelf" solutions for on-line moisture measurements in granulate materials. The focus of this thesis is on-line measurements of moisture in iron ore concentrate. The moisture content of the concentrate is very important to the quality of the manufactured pellets. The water concentration within the concentrate might vary considerably compared to the water content at the surface. This makes it difficult to use remote sensing technologies such as IR, NIR etc. Hence, the long term objective of this project is to develop a low price sensor that can be embedded into the concentrate and make on-line measurements. The probe would most likely be an embedded system, preferably communicating with Radio Frequency Identification technology (RFID). However, this vision can only be realized, in conjunction with a robust measurement method. This thesis investigates two different methods that utilizes fundamentally different physical properties of the material to detect water: both of which might be suitable to incorporate into an RFID tag. The properties investigated are changes in heat conduction and changes in electrical capacitance of the system as the mositure content varies. The first method is frequently referred to in literature as the Dual-Probe Heat-Pulse or DPHP and is based on the principe how heat transfer in a granulate material. The second method is named Capacitance Probe method (CP) where a parallel plate capacitor is used to drive a clock circuit. The frequency in the resonant circuit is determined by the electrical properties of the concentrate, which in turn is dependent on the moisture content. In order to thoroughly evaluate the two methods they were first analyzed theoretically. The purpose of the theoretical study was to optimize the design of the experimental equipment. With the acquired information a measurement system was constructed. Some problems with the design did eventhough occur, the scale of the heat probes were to large, leading to very long response times an poor signal to noise ratio. To the capacitance probe, there were problems to spread the concentrate evenly between the capacitor plates. Two sets of measurements were performed. First, a number of experiments in the laboratory, with the water content kept at controlled levels, then to test the performance of the developed system in an industrial environment a second set of experiments were conducted at a concentrate silo at the LKAB pellet plant in Kiruna. The outcome of the experiments performed in laboratory showed that both methods could detect water in iron ore concentrate. The standard deviation of the measurements of the capacitance probe method was 0.35% (mass percent) moisture. The Dual-Probe Heat-Pulse method showed random disturbances, but a clear correlation was detected. Unfortunately the capacitance probe method measurements at LKAB were inconclusive. The Dual-Probe Heat-Pulse method could, with measurements of the dry density of the material, show a correlation between water content and changes in heat conduction. One of the causes of the inconclusiveness at LKAB are discrepancies in packing density. When wate...

...läs fortsättningen genom att logga in dig.

Medlemskap krävs

För att komma åt allt innehåll på Mimers Brunn måste du vara medlem och inloggad.
Kontot skapar du endast via facebook.

Källor för arbetet

Saknas

Kommentera arbetet: Aquametry in granulate materials

 
Tack för din kommentar! Ladda om sidan för att se den. ×
Det verkar som att du glömde skriva något ×
Du måste vara inloggad för att kunna kommentera. ×
Något verkar ha gått fel med din kommentar, försök igen! ×

Kommentarer på arbetet

Inga kommentarer än :(

Liknande arbeten

Källhänvisning

Inactive member [2005-01-01]   Aquametry in granulate materials
Mimers Brunn [Online]. https://mimersbrunn.se/article?id=48690 [2024-05-18]

Rapportera det här arbetet

Är det något du ogillar med arbetet? Rapportera
Vad är problemet?



Mimers Brunns personal granskar flaggade arbeten kontinuerligt för att upptäcka om något strider mot riktlinjerna för webbplatsen. Arbeten som inte följer riktlinjerna tas bort och upprepade överträdelser kan leda till att användarens konto avslutas.
Din rapportering har mottagits, tack så mycket. ×
Du måste vara inloggad för att kunna rapportera arbeten. ×
Något verkar ha gått fel med din rapportering, försök igen. ×
Det verkar som om du har glömt något att specificera ×
Du har redan rapporterat det här arbetet. Vi gör vårt bästa för att så snabbt som möjligt granska arbetet. ×