Analysis of a new district heating line : Evaluation of heat losses and hydraulic facilities

883 visningar
uppladdat: 2008-01-01
Inactive member

Inactive member

Nedanstående innehåll är skapat av Mimers Brunns besökare. Kommentera arbete
The aim of the project is to analyze the enlargement of the district heating line located in Gävle, evaluating the hydraulic facilities and calculating the heat losses with different insulation thicknesses to choose the best insulation thickness for the pipes. To choose the best thickness, different insulation thicknesses have been evaluated calculating the heat losses for each insulation thickness. To manage the heat losses problem, the pipe length has been divided into threestretches, underground pipe, sea pipe and air pipe. These three stretches have different boundary conditions, and each stretch has been calculated separately. The best thermal solution is choosing the insulation of 0.5m of thickness, but the best thermal solution is not the best solution for this project due to the elevated cost of this thickness in one of the stretches of the line. The pipe crossing the seahas to be on the bottom and to keep the pipe on the bottom concrete is going to be added. The quantity of concrete needed depends on the floatability of the pipe and specifically depends on the insulation thickness. The insulation is a porous material and its density is very small, therefore it has a high floatability. The finalselection is a multi-thickness insulation, with different insulation thicknesses in the different stretches, 0.6m of thickness in the underground and air pipe and 0.3m of thickness in the sea pipe. With this configuration the heat losses are quite close to the optimum case. The purpose in the hydraulic study has been quantifying the start pressure in the new line to fulfil the energy demand in the worst point of the line. With 320kPa at the start of line, the pressure in the worst point is enough to fulfil the nowadaysdemand, 3MW, and in the future when this line will be enlarged and the demand increased to 20MW, the pressure at the start of the line to ensure the reques...

...läs fortsättningen genom att logga in dig.

Medlemskap krävs

För att komma åt allt innehåll på Mimers Brunn måste du vara medlem och inloggad.
Kontot skapar du endast via facebook.

Källor för arbetet

Saknas

Kommentera arbetet: Analysis of a new district heating line : Evaluation of heat losses and hydraulic facilities

 
Tack för din kommentar! Ladda om sidan för att se den. ×
Det verkar som att du glömde skriva något ×
Du måste vara inloggad för att kunna kommentera. ×
Något verkar ha gått fel med din kommentar, försök igen! ×

Kommentarer på arbetet

Inga kommentarer än :(

Liknande arbeten

Källhänvisning

Inactive member [2008-01-01]   Analysis of a new district heating line : Evaluation of heat losses and hydraulic facilities
Mimers Brunn [Online]. https://mimersbrunn.se/article?id=54231 [2024-04-28]

Rapportera det här arbetet

Är det något du ogillar med arbetet? Rapportera
Vad är problemet?



Mimers Brunns personal granskar flaggade arbeten kontinuerligt för att upptäcka om något strider mot riktlinjerna för webbplatsen. Arbeten som inte följer riktlinjerna tas bort och upprepade överträdelser kan leda till att användarens konto avslutas.
Din rapportering har mottagits, tack så mycket. ×
Du måste vara inloggad för att kunna rapportera arbeten. ×
Något verkar ha gått fel med din rapportering, försök igen. ×
Det verkar som om du har glömt något att specificera ×
Du har redan rapporterat det här arbetet. Vi gör vårt bästa för att så snabbt som möjligt granska arbetet. ×