Detta arbete presenteras i samarbete med LIBRIS/Uppsök

Sammanfattning: Composite bridges are used for road and railroad bridges in Sweden and
worldwide. The advantage of composite bridges is that concrete and steel is
used optimally, steel in tension and concrete in compression. In order to
get the interaction between steel and concrete headed stud shear connectors
are used.
Fatigue loading makes cracks, initiated by welding, propagate and in this
way the strength of shear connectors are decreased during the fatigue life.
The aim in this thesis is to investigate the residual strength of 22 mm
headed stud connectors and if possible derive an equation for residual
strength. In BV BRO the residual strength is neglected in design of ultimate
limit state, but in e.g. Eurocode and BRO 2002 it is taken into account. One
objective is to evaluate the assumption made in BV BRO.
A state of art on the subject has been performed. Most previous research is
focused on the endurance rather than residual strength, but some relevant
research was found. From previous research and literature the fatigue life
was found to be mainly affected by the range and the peak load.
A literature survey on fatigue, fracture mechanics and the behaviour of
shear studs have been performed to improve the understanding of the subject.
The experimental work carried out within this master's thesis is 10 push-out
tests, five static and five fatigue. The push-out specimens were made
according to Eurocode 4 and the headed shear studs used were 125 x 22mm.
Differences and similarities in Swedish design standards and Eurocode have
been investigated. These design standards have also been compared to
experimental results and to previous research.
The results of tests and literary survey show that the residual strength
under fatigue loading constantly ...
Medlemskap krävs
För att komma åt denna sida måste du
vara medlem och inloggad.
Är du inte redan medlem?